11/04/2023
Realizzazione di impianto ventilazione meccanica locali laboratorio cottura ristorante rione Monti in Roma. L'impianto ha una portata totale di circa 20.000 Nmc/h con mitigazione olfattiva ed acustica. Impianto con portata variabile coniugata fra estrazione e reintegro.
The air flow control system was tested at the Bank of Italy on a system with aeraulic circuits in the printing machine process air extraction, VOC and heat disposal. The system maintains the flow rate as the pressure drop of the filters varies between the beginning and end of their life. A 4" touchscreen HMI operator panel was used, and the native PLC equipment of the H100 inverter was used, LS electric products with system development by the Italian division. System consisting of 3 new aeraulic circuits, each with its own control structure also equipped of manual backup system and emergency service https://www.fantech.biz/blog-news/flowrate-controller-tested
Laboratory for cooking meat with solid fuel, treatment of combustion effluents and cooking vapors. Total nominal system air flow rate 30,000 Nmc/h treated fluid temperatures 20-200°C.
Construction of a mechanical ventilation system for the production premises of a restaurant in the Dolce Vita district in Rome. Air treated for about 35,000 m3/h. Cooking rooms equipped with extractor ceiling with approximately 24,000 m3/h treated. Cooking vapor exhalation circuit with elimination of oil mists (demisting) and fine particulate. External air replenishment circuit with fine particle filtration and heat treatment. Electric power for mechanical ventilation 48 kw @400v. Acoustic mitigation of all aeraulic circuits.
Construction of a mechanical ventilation system for restaurant production premises in the historic trident in Rome. The plant has a flow rate of 7,000 m3/h in extraction and a reintegration of extracted air with external air divided into the environment and a filtered and thermally treated counter hood for about 6,000 m3/h. Filtered extraction by means of demister oil mist units, external air filtered for fine dust. Acoustic mitigation of exhalation circuit and external air intake.
Design & procurement for mechanical ventilation system for cooking laboratory rooms in an oriental restaurant in the Veneto area of Rome. Total treated air flow rate 20,000 m3/h. acoustic mitigation of aeraulic circuits.
Plant in the modeling phase at the service of laboratory activities in the municipality of Rome. Total extraction rate and emission into the atmosphere of cooking and washing hoods 5,500 Nmc / h, external air input flow rate into the environment 4,500 mc / h.
Mechanical ventilation system kitchen laboratory Rome historic center. 3D executive design, fluid dynamics simulation for noise detection.
Construction of a mechanical ventilation system for the local cooking laboratory in the historic center of Rome. The plant has a flow rate of 12,000 cubic meters / h in extraction and a reintegration of extracted air with filtered and treated external air for approximately 10,000 cubic meters / h.
3D virtual model of the plant under construction of the Hotel restaurant kitchen in the province of Rome. Total extraction rate and emission into the atmosphere of cooking and washing hoods 12,000 Nm3 / h, balancing flow rate of counter-hoods 5000 Nm / h, introduction of external air into the environment 5000 m3 / h Mechanical ventilation system performance 40 vol / h. Total installed power 10.5 kw. Noise level at the emission chimney <60 dB (A).
Mechanical ventilation system for production areas and air conditioning. The air conditioning system has been designed excluding any form of recirculation. Use of external air only for air conditioning machines, with high efficiency heat recovery units, ERP compliance, with efficiencies> 90%. In accordance with the recommendations of the Higher Institute of Health and AICARR recommendations, for safe environments for hospitality, according to the VentOsan development project.
Revamping of the mechanical ventilation system for the flexographic printing process. Dust filtration, VOC adsorption, acoustic mitigation and air flow control with management of redundancies in emergency service. Total treated air flow rate 18,000 Nmc/h.